November 2012

Dear Sir or Madam,

With the aim of continual improvement, Carlor Engineering has decided to replace the Wilo Z Nova pumps with Vortex pumps on its Topstarts W (TSWZ). The Vortex pumps can also be mounted on old Topstart W as the rotor is compatible with our current heating bodies.

These German pumps benefit from a wider temperature range that is more adapted to our heaters. In addition, the pump technology allows an easy cleaning or replacement of the rotor in case the pump is blocked by dirt. Finally, this pump has a higher flow and delivery head compare to the previous Wilo Z. The Vortex pump has the following specifications :

image4

  • Max. delivery head : 1,25m.
  • Max. flow : 640l/h.
  • Max. pressure : 10 bars.
  • Max. temperature : 95°c.
  • Protection class : IP42 or IP66 on request after modification by Carlor.
  • Power consumption : 26W.

The Carlor Engineering team hopes you will appreciate the efforts made to continuously improve the products of the Carlor range. We stay at your disposal if you have any question or remark.

Best Regards,

Sébastien Peutat, Sales Manager

Denis Léonard, Production Manager